diff --git a/platforms/app/main.c b/platforms/app/main.c index 64fdf08..9e20f9d 100644 --- a/platforms/app/main.c +++ b/platforms/app/main.c @@ -21,7 +21,8 @@ * You can generate a metered version from any wasm file automatically, using * https://github.com/ewasm/wasm-metering */ -#define GAS_LIMIT 2000000000000 +#define GAS_LIMIT 500000000 +#define GAS_FACTOR 10000LL #define MAX_MODULES 16 @@ -39,7 +40,7 @@ int wasm_bins_qty = 0; #if defined(GAS_LIMIT) -static int64_t current_gas = GAS_LIMIT; +static int64_t current_gas = GAS_FACTOR * GAS_LIMIT; static bool is_gas_metered = false; m3ApiRawFunction(metering_usegas) @@ -79,7 +80,7 @@ M3Result link_all (IM3Module module) #if defined(GAS_LIMIT) res = m3_LinkRawFunction (module, "metering", "usegas", "v(i)", &metering_usegas); if (!res) { - fprintf(stderr, "Warning: Gas is limited to %0.4f\n", (double)(current_gas)/10000); + fprintf(stderr, "Warning: Gas is limited to %0.4f\n", (double)(current_gas) / GAS_FACTOR); is_gas_metered = true; } if (res == m3Err_functionLookupFailed) { res = NULL; } @@ -259,7 +260,7 @@ M3Result repl_call (const char* name, int argc, const char* argv[]) #if defined(GAS_LIMIT) if (is_gas_metered) { - fprintf(stderr, "Gas used: %0.4f\n", (double)(GAS_LIMIT - current_gas)/10000); + fprintf(stderr, "Gas used: %0.4f\n", (double)((GAS_FACTOR * GAS_LIMIT) - current_gas) / GAS_FACTOR); } #endif